Novastar NovaPro HD LED Video Processor

£3,450.00

Novastar NovaPro HD LED Video Processor

1.The NovaPro HD is a professional LED display processor. Besides the function of display control, it also features in powerful front end processing, so an external scalar is no longer needed. With professional interfaces integrated, NovaPro HD meets the requirements of broadcast industry, in image quality and in control.
2.The inputs of the NovaPro HD include CVBS, VGA, SDI, DVI, HDMI and DP. They support input resolution up to 1080p@60Hz. Highest pixel clock is 165MHz. Output bandwidth is up to 4GBit. Advanced de-interlacing motion adaptive processing technology is adopted so that images are clear and fine. And with HDMI, the gray scale depth can be up to 12bits.
3.Each input can be fully configured with contrast, brightness, hue, saturation, and RGB gain. Inputs can be scaled up or down to fit the LED display resolution.
4.Computer software for system configuration is not necessary. The system can be configured using one wheel and one button. All can be done just by fingers.
5.That’s what we called Touch Track! You can also configure the system with browsers. This gives you the option of using a remote PC (Windows or Mac or Linux), a pad or even a smart phone to do the configuration. Real-time previews assist with system set-up and confirm source status.
6.The NovaPro HD video processor has DMX512 and GenLock interface. Professional control and synchronization are ready to go. Optical fiber outputs enable the confidentlong-distance data transmission.
7.The NovaPro HD video processor is the flagship product of our new generation controllers, powerful in processing, professional in control, and friendly in user-interface. Having a display to work has never been as easier and more enjoyable as with NovaPro HD.
 
Input
Port Amount Resolution specification
CVBS 1 PAL/NTSC
VGA 1 VESA standard
DVI 1 VESA standard (support 1080i input) and support HDCP
HDMI 1 EIA/CEA-861 standard, conforming to HDMI-1.3 standard and supporting HDCP
DP 1 VESA standard
3G-SDI 1 480i, 576i, 720p, 1080i/p(3G SDI)
Output Index
Port Amount Resolution specification
DVI input looping out (DVILOOP) 1 Consistent with DVI input and does not support HDCP loping out
DVI 2 1280×1024/60Hz 1440×900/60Hz 1680×1050/60Hz 1600×1200/60Hz 1600×1200/60Hz – Reduced 1920×1080/60Hz/50Hz 2560×816/60Hz 2048×640/60Hz 1920×1200/60Hz 2304×1152/60Hz 2048×1152/60Hz 1024×1280/60Hz 1536×1536/60Hz User-defined output resolution (bandwidth optimization) Horizontal resolution: maximum 3840 pixels Vertical resolution: maximum 1920 pixels
HDMI 1
SDI input looping out (SDILOOP) 1 480i, 576i, 720p, 1080i/p(3G SDI)
Specification of complete machine
Input power 85-265VAC 50/60HZ 0.65A
Overall power consumption 30W
Operating temperature -20~60C
Weight 6KG
Overview

NovaPro HD is a professional LED display controller. Besides the function of display control, it also features in powerful front-end processing. It has integrated various professional interfaces. With excellent image quality and free image control, NovaPro HD has greatly satisfied the requirements of display industry.
Product features:

Appearance
Front Panel
NovaPro HD front panel

1) Power switch
Indicator light
2) Green– indicator of operating status. It blinks normally when the controller operates properly. It blinks slowly when there is no video signal input. It blinks like breathing when there are Ethernet ports of this unit in hot backup state.
Red- Power indicator

3) Option buttons of six input sources and below is corresponding indicator lights. Short press a button to set it as the input source of main screen while long press
to set as the source of PIP. Result of the operation can be viewed on operation screen during setting.

4) Operation screen (Please see details in the subsequent Chapter: Main Interface).
5)Knob: Enter by pressing the knob and select or adjust by turning the knob.
6)ESC: Exit current operation or option.

7)BLK: LED Display is blank screen. Indicator light is blue by default after power on and it turns green when BLK is enabled;
FRZ: Images on LED Display are frozen. Indicator light is blue by default after
power on and it turns green when enabled;
PIP: Display PIP. Indicator light is blue by default after power on and it turns
green when enabled;
8): Type A female interface is USB interface to connect U disk to import configuration file or update programs. Type B female interface is USB control interface to connect PC for communication.

Rear Panel
NovaPro HD rear panel
Inputs
Audio
Audio Input
DP
DP Input
HDMI
HDMI Input
DVI
DVI Input
VGA
VGA Input
CVBS
PAL/NTSC TV Composite Video Inputs
3G-SDI IN
3G-SDI Input
Genlock IN
Synchronizing signal to guarantee the images on display
is synchronous with external Genlock source.
Output
3G-SDI LOOP
3G-SDI Loop out
GenLock LOOP
Genlock Loop out
DVI LOOP
DVI Loop out
Monitor -DVI
Monitoring Interface
Monitor -HDMI
LED Out 1, 2, 3, 4
4-Channel Ethernet Outputs
OPT Output 1, 2, 3, 4
4-Channel Optical Fiber Outputs
Control Interface
Control Interface
Ethernet Control (connecting PC for communication or accessing Network)
USB Contro
IN: connecting PC for communication or cascade input; connecting USB OUT of last NovaPro HD
OUT: cascade output, Cascading USB IN of next NovaPro HD
DMX Control
IN: connecting all consoles that support DMX512 interface protocol.
LOOP: DMX512 signal Loop output
Power
AC 100-250V~50/60HZ
AC Power Interface
Signal Connection

Signal Connection
Connect the required hardware devices referring to the interface descriptions in
previous chapters.
Note: Please turn OFF POWER before signal connection.

NovaPro HD video single connection
Multiple Units Connection Sketch
NovaPro HD video sourch connection

Description of Operation Modes

NovaPro HD is not only powerful in functions but also easy to use. It supports three operating modes for users to choose in different occasions.

Note: Interlace operation of machine, LCT and Web is not allowed. Please refer to the following chapter for detailed operation steps.

Machine Operation

LED display can be started with moderate brightness and used normally through five simple steps. Menus of Display Control, Advanced Settings, Communication Settings and Language can help users to better control LED display

Description of operation action

Knob: Press the knob to enter into menu and turn it to adjust values or select
submenus. At this time, enter into the submenus or confirm adjusted values by
pressing the knob.
【ESC】: Return key, exit from current menu or operation.
Option buttons of six input sources: Short press a button to set it as the input source
of main screen while long press to set as the source of PIP.
Lock: simultaneously press the knob and ESC button for more than three seconds to lock the controller.

Unlocking: simultaneously press the knob and ESC button for more than three seconds to unlock the controller.

Main Interface

Interface-LCD-display

First row: product model, local IP/ device name (custom)

INPUT:
Main screen, signal source, input source signal format. PIP, signal source, input source signal format.
OUTPUT:
Output signal format of LED display.
LED Output, Currently it is Port2 output.

STATE

Status bar, meanings of each icon are described as below:

Status bar
Primary
It denotes that the controller is in primary control mode.
Backup
It denotes that the controller is in backup mode.
80%.
Current brightness is 80%.
37 deg C
When the temperature of NovaPro HD exceeds threshold value (able to be changed by users), the temperature value will turn red and blinks
5.0v
When the voltage of NovaPro HD exceeds threshold value (able to be changed by users), the voltage value will turn red and blinks.
 
Current effect is point-to-point display
 
Scaling down mode
 
Scaling up mode
 
It denotes that there is Genlock synchronous signal input
 
It denotes that DMX channel signal is enabled
 
It is USB control currently.
 
It is Ethernet Port control currently
 
Image Mosaic enable
 
Button lock icon, functions of the buttons and knob are locked when this icon appears on the main interface
 
It denotes that the controller is not locked

Step 1: Input Settings

Set the resolution of the input source signal. Resolution can be directly set and changed through NovaPro HD for digital input modes: DVI, HDMI, and DP. For other input modes, the resolution can only be changed on input devices. Input resolution can be set in two ways: 

I: Preset Resolution

Choose a suitable resolution from the standard resolutions preset in the controller. If there is no suitable resolution.

Preset-Resolution

II: Custom Resolution

Set custom width, height, refresh rate. Then turn the knob to select “Apply” and press the knob to confirm and apply. If not confirmed, the custom resolution settings will be unavailable.

Custom-Resolution

Step 2: Screen Settings

Preconditions of screen settings:

1) Each Ethernet port must load the same number of cabinets (If the number of cabinets is not integer multiples of the Ethernet ports, the remaining cabinets will
be loaded by the last Ethernet port); 

2) Regular screen, regular cabinets, each cabinet with the same size.
Operating steps of screen settings:
Step 1 Turn on the power of LED display. If the cabinets display normally, go to step
2. If the cabinets display abnormally, it is required to load the cabinet file first and save it to receiving card. Please see detailed operations in Advanced Settings.

Step 2 : Enter into the submenu of “Screen Settings” submenu. The options are shown in the following figure:

Screen-Settings

Step 3 Set Cabinet Row QTY and Cabinet Column QTY according to the actual
situation of the screen.

Step 4 Set Port1 Cabinet QTY. The device has some limitations on the cabinet quantity of network interfaces. For details, see precautions for screen setting a). The
controller has certain limitations to the quantity of cabinet loaded by an Ethernet
port. Please see details in Notes a) of Screen Settings.

Step 5 Set data flow of the screen and please see the Notes c), d), e) of screen settings.

Step 5
a) If the number of ports with loads is n (n≤4), the quantities of cabinets loaded by each of the first n-1 ports must be equal (If the quantity of cabinet loaded by each port are different, please choose Advanced Config and view details in Advanced Configuration) and also be an integral multiple of the quantities of cabinet rows or columns and, meanwhile, be greater than or equal to the quantities of cabinets loaded by the nth port Example: If Port 1, Port 2, Port 3 have loads, cabinet quantity of Port 1 and Port 2 must be equal and also be an integral multiple of the quantity of cabinet row or column. As a result, set Port 1 Cabinet Qty only according to actual situation during screen settings. The quantity of receiving card loaded by Port 3 ≤ the quantity of cabinet loaded by Port 1.
b) In case of special-shaped cabinets, cabinets with different size and special-shaped screen, the software NovaLCT-Mars is required to be connected to configure the screen.
c) During Data Flow setting, turn the knob to see the results of different types of data flow on the screen in real time. If satisfied with the current data flow, you must press the knob to save the setting. Press return key to exit from current operation.
d)During Data Flow setting, make sure that the data flow of each port is connected along the same direction.
e) During Data Flow setting, make sure that the start position of Port 1 is the start position of whole

Step 3: Brightness Control

Return to main menu interface. Press the knob and select the corresponding value. At this time, the knob can be turned to adjust brightness value.

Brightness-Control

Step4:: Output Settings

Output settings can be divided into three cases:

I: Point-to-point display, namely, scaling disabled. Size of the output image is the same as the input image and the output is based on original proportion.
The horizontal and vertical offset of the image are set as required and operation steps are shown in the figure below

custom-scaling
input-sources-led-display
II: The output image is adjusted to the size of the display screen, namely it is self-adaptive to the size of the display screen.
Operation: Enable scaling and auto fit to screen
Enable-scaling-and-auto-fit-to-screen.

III: Custom Scaling
Operation: Enable Scaling and disable Auto Fit To Screen to customize scaling.

Operating steps of custom scaling:

a) Input Capture setting, i.e., to capture the part of the image from one start
position of the input image and display it on the LED screen. It is needed to
set horizontal width(≤horizontal resolution of input source) and vertical
height(≤vertical resolution of input source) as well as start X(horizontal start)
and start Y(vertical start).

custom-scalling-full

B) Output Window setting, size of the window is smaller than or equal to the
size of LED display. After window is set, images can only be displayed within
the range of the window and be self-adapted to the size of the window.

output-window-setting

After setting according to the above two steps, the captured content will be only
displayed on the set area of the LED display, as shown below:

Display Contro

display-control
  •  Normal
  • Freeze: same as the function of FRZ button.
  • Black Out: same as the function of BLK button.
  • Test Pattern
test-patten
Picture quality adjustment

Set contrast, saturation, hue, sharpness, color temperature, red brightness, green
brightness, blue brightness and Gamma as required. Save these parameters to
hardware after adjusting to satisfaction

Picture-quality-adjustment
channel-effect

Channel Effect

The software supports three effects: cut, fade and pop-up. Select Off to if off to switch off Channel Effect.

Advanced Settings

Several options of major function setting are included in advanced settings, as shown in the figure below, including PIP, Advanced Configuration, Montage, etc. Operation of each function will be detailed for users in the following chapter.

advance-setting

Picture in Picture (PIP)

To switch on or off PIP and set the input source of main screen as well as the size,  position and transparency of PIP and PIP crop settings.

PIP: Switching on/off PIP is the same as the function of PIP button on front panel and synchronous with it.
Main source/PIP source: Input source switching of main screen and PIP is the same as the function of input source switching button on front panel.
Width (H): Horizontal width of PIP
Height (V): Vertical height of PIP
Start X: Horizontal coordinates of PIP
Start Y: Vertical coordinates of PIP
Transparency: Transparency of PIP
PIP Crop Settings:
Image cropped from the set starting position will be displayed on PIP and its size is the set horizontal width and vertical height. Please enable this function before setting horizontal width, vertical height, start X and start Y.

pip-crop-enable

Advanced Configuration

If the number of cabinets loaded by each Ethernet port is different and the preconditions of screen settings are not met, the advanced configuration can be used now. The operating steps of advanced configuration are shown below:

advance-config

1) Enable Advanced Config

Please enable Advanced Config first since it is disabled by default in NovaPro HD. Advanced Config defaults to “Disabled”. After the function is enabled, the rows and
columns of the cabinets loaded by each port, offset, and data flow can be set respectively.

1) Ethernet Port Settings

Set the rows and columns of the cabinets loaded by each port, horizontal and vertical offset as well as data flow according to the actual layout of the cabinets.

Ethernet-Port-Settings
Precautions for advanced mapping screen:
Primary
a) If the cabinets are irregular shaped and the sizes are different and the LED screen is also irregular shaped, the software NovaLCT-Mars is required to be connected to configure LED display
Backup
b) When wiring method is set, real-time effect of different wirings can be displayed on the display screen by turning the knob. If you are satisfied, you must press the knob once to save the setting and press return key to exit the current operation. During data flow setting, turn the knob and the results can be viewed on the LED display in real time. Press the knob to save your setting if you are satisfied with it and then press return button to exit from current operation.

After Port Settings are completed, select “Apply” and press the knob to apply current settings. If you want to quit the settings, select “Return”.

Montage

For oversized LED display, two or more NovaPro HD units are needed for the montage. In this case, the loading area of each NovaPro HD unit needs to be set respectively. Enable Montage first and set the total width and height of the LED display. Then set the size and starting position of the loading area of the NovaPro HD unit. The total sizes of the loading area of all NovaPro HD units are the total sizes of LED displays.

montage

Montage Example: the total number of pixels of the LED display is 4000×1000, which has exceeded the load of a single Pro HD unit. Montage can be applied and two Pro HD units can be used for montage. See detailed parameter settings and the connections in the chart and figure below.

Pro HD(1) Pro HD(2)
Total Width(H)
4000
Total Height(V)
1000
Load Area Width
2000
2000
Load Area Height
1000
1000
Load Area X
2000
Load Area Y
Montage-Connections

Note: If montage is to be enabled, please ensure Output Settings is in the third case: Custom Scaling, namely, set Scaling as enable while Custom Scaling as disable

Load Cabinet File

Connect NovaPro HD to PC and run NovaLCT-Mars on PC. Import cabinet configuration file saved before into the controller.

1) Save the cabinet configuration file
After receiving card is configured, click Save File to save the cabinet configuration file (.rcfg) to the local file on the PC.

Custom-Resolution

2) Import cabinet configuration file into NovaPro HD.
Operating steps are shown in the figure below

mport-cabinet-configuration-file-into-NovaPro-HD.

3) Load Cabinet File

Load-Cabinet-File

Alarm Threshold Settings

Set the threshold values of temperature and voltage. When temperature or voltage of NovaPro HD exceeds the threshold value, temperature or voltage on the home page
of the screen will turn red and blink.

Alarm-Threshold-Settings

Advanced Property

Set the threshold values of temperature and voltage. When temperature or voltage of NovaPro HD exceeds the threshold value, temperature or voltage on the home page
of the screen will turn red and blink.

Advanced-Property

Including following functions:

  • VGA Auto Adj: sampling parameters of VGA input signal are automatically adjusted so that VGA image is clear and complete. Select this menu and then press the knob once to perform VGA automatic adjustment once. 
  • ADC Calibration: Images will be color cast or darker etc. when analog signal is accessed into processors without ADC calibration. NovaPro HD is able to automatically perform ADC calibration based on input analog signal (including CVBS and VGA) to solve above problems. Select this menu and then press the knob once to perform ADC calibration once.
  • DNR Settings: It is available when image input port is not VGA and there are five
    modes of noise reduction: “Off”, “Auto”, “Low”, “Medium” and “High”.

Save parameters to hardware

Save all the configurations of NovaPro HD to hardware and the data will not be lost after power off.

Advanced-Property

Including following functions:

  • VGA Auto Adj: sampling parameters of VGA input signal are automatically adjusted so that VGA image is clear and complete. Select this menu and then press the knob once to perform VGA automatic adjustment once. 
  • ADC Calibration: Images will be color cast or darker etc. when analog signal is accessed into processors without ADC calibration. NovaPro HD is able to automatically perform ADC calibration based on input analog signal (including CVBS and VGA) to solve above problems. Select this menu and then press the knob once to perform ADC calibration once.
  • DNR Settings: It is available when image input port is not VGA and there are five
    modes of noise reduction: “Off”, “Auto”, “Low”, “Medium” and “High”.

Redundancy

Set this controller as primary control or backup. “Primary” or “Backup” will be displayed on the main interface.

Redundancy

DMX512 Channel Settings

Set the starting channel of DMX512. NovaPro HD currently has extracted 16 property channels. 0~8 have been defined with properties and the rest are not defined for the
moment. 

For example, if the starting channel is set as 1, the controller will take 16 channels from the 1st channel as available channels.

Channel No. Property Definition
Global Brightness of LED display
1
Contrast
2
Saturation
3
Hue
04
Color temperature
5
Red component brightness
6
Green component brightness
7
Blue component brightness
8
Gamma
9
Undefined
10
Undefined
11
Undefined
12
Undefined
13
Undefined
14
Undefined
15
Undefined

Factory Reset

Restore NovaPro HD to factory settings

Hardware version

View hardware version of NovaPro HD.

Communication Settings

Set the communication mode and network parameters of NovaPro HD. There are two communication modes, one is USB Preferred and the other is LAN
Preferred. If both USB and LAN ports are connected to the control computer and LAN Preferred is selected, the system will use LAN to control. If only USB port is connected, the setting will be unavailable and system will use USB to control.  Network modes include “Manually” and “Automatically”. It is obtained through DHCP while in “Automatically” mode

Communication-Settings

Language Settings

NovaPro HD supports Chinese and English at present.

Web Interface Operation

Access Web control interface of Pro HD through browser. Main operating steps, functions and corresponding parameter configuration requirements are the same as the operation of the controller. This chapter only covers network establishment, motion description and features of Web interface operations. Please refer to the relevant chapters of controller operation for specific parameter configurations and configuration requirements.

Network Establishment

  1. Connect Pro HD to the same LAN and network segment as the control
    computer.
  2. Turn on the power of Pro HD and set communication settings on the controller referring to 7.9 Communication Setting. Local IP can be obtained automatically or manually if you know the IP address.
  3. Open up the browser on control computer. Enter the local IP of Pro HD and open up the web configuration interface.

Operating Motion Description

The Web interface of Pro HD is shown as the picture below. Compared with controller operation, the operation with Web interface is more intuitional and clearer.

Operating-Motion-Description

Toolbar: The toolbar will be highlighted when you move the mouse over it. By clicking the toolbar, you can get into the configuration pages of sub menus. The
functions are the same as the menus in the bottom left of the page. 

Menu bar: click the mouse and enter the parameter configuration interface in the main menu. If there are sub menus, sub menu bar will pop out.

Six input source switching buttons: the input source of the main screen can be switched with mouse clicking. The switching of the input source of PIP needs to enter “Advanced Settings” → “PIP” sub menu interface settings, as shown in the figure below

Three display control buttons: the indicator lights default to blue and turn green
when enabled.

My Device

The name of the device can be modified, which is a unique function of Web interface operation.

my-devices

LCT Client Operation

Communication between control computer and Pro HD is via USB control cable. Compared with the operation through controller and Web, LCT client can provide
users with the most comprehensive functions and configuration parameters. The main functions include screen configuration, brightness adjustment, monitoring, calibration, etc. Please refer to Nova M3 Control System User Manual for specific operations of these functions. Operation interface of LCT client is shown as the figure below:

LCT-Client-Operation

Firmware Upgrade

There are two ways to upgrade the firmware of Pro HD: upgrade by U disk and LCT client.
1) Upgrading firmware by U disk
Firmware upgrade by U disk must meet two conditions:
a) The format of the U-disk must be FAT12/16/32。
b) Software package must extract to the root directory of the U-disk.
There are two ways to upgrade firmware by U-disk: a) Plug U disk into the USB port
on the front panel. Press FRZ button and PIP button simultaneously when turning on power and the unit will enter firmware upgrade mode. b) Plug in U disk after power on. Choose whether to upgrade or not according to prompt.
2) Upgrading firmware by LCT client
Connect Pro HD to PC and run NovaLCT-Mars on PC. Log in advanced user and the
password is “admin”. Then click “admin” on you keyboard after logging in and the program loading page will pop up.

Firmware-Upgrade

Current operation communication port: Choose the serial port, the hardware program of which is to be upgraded.
Program path: Select the hardware program to be upgrade currently.
Sending card: Check to update all the programs of sending card. FPGA of receiving card: Check to update FPGA program of receiving card.
Update: Change hardware program into hardware device.

Refresh all: Check this option and click Refresh to refresh and display the program versions of all sending card and receiving card of current serial port.
Set refresh: Click “Refresh” to set refresh and display the version information of one receiving card.
Refresh: Refresh and display the version information of hardware in order to 刷 make sure the hardware program is updated.

Troubleshooting and Precautions

Problem Solution
Blank screen of LED display
Check whether the power is correctly connected and the switch is on. Use test pattern to check whether the LED is correctly connected and is working properly. Check whether Pro HD has signal input and the output is set as black out. Check whether the display configuration mode and parameters are correct.
Monitoring port output is abnormal
Check whether the input channel has image input and it is displayed normally. Check whether PIP is enabled and channel 2 has signal input and the image is displayed normally. Check whether monitor output is connected correctly and the connection is not loose. If connecting Pro to display, please confirm whether the display supports the output resolution of Pro. Try to cut the power and restart the device. Then reset Pro and do the operations again
VGA input phase offset
Perform VGA auto fit
PIP displays abnormally
Check whether channel 2 has signal input and it is displayed normally. Check whether the parameter settings of PIP are correct
Channel effect is abnormal
Check whether channel is switched on.
Montage is abnormal
Check whether montage is enabled and the parameter settings are correct. Check whether input signal is normal.
Precautions
  1. This product only supports rectangular screen composed of
    cabinets with same size and specifications for machine
    configuration. Irregular cabinets and screens need to be
    configured on LCT client.
  2. It is not recommended to alternately operate one LED display via machine operation, Web operation and LCT client
    operation.

Please troubleshoot the devices according to above steps. If problems cannot be solved, please contact our local dealers or customer service department. Since there are components with high voltage inside the controller, please DO NOT maintain it by yourself for the sake of your safety

Technical Specifications

Inputs
Port
Number
Resolution ratio specs
CVBS
1
VESA standard
DVI
1
VESA standard (supporting 1080i input), supporting HDCP
VGA
1
VESA standard
HDMI
1
EIA/CEA-861 standard, in accordance with HDMI1.3standard, supporting HDCP
DP
1
VESA standard
3G-SDI
1
480i、576i、720p、1080i/p(3G SDI)
Outputs
Port
Number
Resolution ratio specs
DVI input loop (DVILOOP)
1
In accordance with DVI input, supporting HDCP loop
DVI
2

1280×1024/60Hz 1440×900/60Hz
1680×1050/60Hz 1600×1200/60Hz
1600×1200/60Hz – Reduced
1920×1080/60Hz/50Hz 2560×816/60Hz
2048×640/60Hz 1920×1200/60Hz
2304×1152/60Hz 2048×1152/60Hz
1024×1280/60Hz 1536×1536/60Hz
Custom output resolution (band-width optimization)
Horizontal resolution up to 3840 pixels
Vertical resolution up to 1920 pixels

HDMI
1
SDI input loop (SDILOOP)
1
480i、576i、720p、1080i/p(3G SDI)
Control Interface
Port
Number
Instruction
USB
2
Upper computer control interface
RJ45
1
Multi-units communication interface
DMX
1
Connected to all kinds of control interfaces that support DMX512 interface protocol.
Overall Specifications
Input power
AC 100-250V, 50/60Hz
Overall power consumption
30W
Operating temperature
-20~60℃
Dimensions(L x W x H)
483×389×88.2(mm)
Weight
6 Kg

Installation Dimensions

Video-Controller-NovaPro-HD-dimensions

Brand

Novastar LED

NOVASTAR LED LOGO
× How can I help you?